By default, Quality of Experience (QoE) data is purged after 60 days. You can use the settings on the Quality of Experience Data page to retain the data for a longer or shorter period of time. If you disable QoE, data that was captured before QoE was enabled will also be subject to purging.

Note:
You should configure call detail recording (CDR) and QoE to retain data for the same number of days. Each call in the call detail reports (CDRs), available from the Monitoring Reports homepage, includes CDR and QoE information. If the purging duration for CDR and QoE is different, some calls may only include CDR data, while other may only include QoE data.

The following procedure describes how to configure purge settings for QoE data.

To specify retention of QoE data by using Lync Server Control Panel

  1. Log on to the computer as a member of the RTCUniversalServerAdmins group, or as a member of the CsVoiceAdministrator, CsServerAdministrator, or CsAdministrator role. For details, see Delegate Setup Permissions.

  2. Open a browser window, and then enter the Admin URL to open the Lync Server Control Panel. For details about the different methods you can use to start Lync Server Control Panel, see Open Lync Server Administrative Tools.

  3. In the left navigation bar, click Monitoring and Archiving, and then click Quality of Experience Data.

  4. On the Quality of Experience Data page, click the appropriate site from the table, click Edit, and then click Show Details.

  5. To turn on purging, select Enable Purging of QoE.

  6. In Keep QoE for maximum duration (days) select the maximum number of days that QoE data should be retained.

  7. Click Commit.

Specifying QoE Retention by Using Windows PowerShell Cmdlets

You can create QoE retention settings by using Windows PowerShell and the Set-CsQoEConfiguration cmdlet. You can run this cmdlet either from the Lync Server 2013 Management Shell or from a remote session of Windows PowerShell. For details about using remote Windows PowerShell to connect to Lync Server, see the Lync Server Windows PowerShell blog article "Quick Start: Managing Microsoft Lync Server 2010 Using Remote PowerShell" at http://go.microsoft.com/fwlink/p/?linkId=255876.

To specify QoE retention for a specific location

  • This command enables purging of QoE data for the Redmond site, and configures the site to maintain QoE data for 20 days.

    Copy Code
    Set-CsQoeConfiguration -Identity "site:Redmond" -EnablePurging -KeepQoEDataForDays 20
    

To specify QoE retention for multiple locations

  • This command configures QoE retention for all the QoE configuration settings in use in an organization.

    Copy Code
    Get-CsQoEConfiguration | Set-CsQoEConfiguration-EnablePurging -KeepQoEDataForDays 20 
    