1. Adaptation name: Lync2013
2. Module name: DigitConversionAdapter
3. Module Parameter: odstd=lab.tekvizion.com
4. Under Digit Conversion for Outgoing Calls from SM:
5. Matching Pattern: 972
6. Min: 10
7. Max: 10
8. Delete Digits: 0
9. Insert Digits: +1
10. Address to modify: both
Figure 29: Adaptation-1
1. Adaptation name:CS1K_adaptation
2. Module name: DigitConversionAdapter
3. Module Parameter: osrcd=lab.tekvizion.com odstd=lab.tekvizion.com
4. Under Digit Conversion for Incoming Calls to SM:
5. Matching Pattern: 1
6. Min: 11
7. Max: 11
8. Delete Digits: 0
9. Insert Digits: +
10. Address to modify: destination
Figure 30: Adaptation-2